WiscNet incident

[2268943] Mishicot Area School District - 400561 - Down

Resolved after 3 hours 49 minutes, affecting Mishicot School District, on July 29, 2026.

postmortem Jul 29, 2026, 06:46 PM UTC

Observed the OSPF adjacency go down as well as the physical interface indicating a loss of connection to the isp router, either due to a fiber cut or the device being unplugged.

Started
Jul 29, 2026, 02:56 PM UTC
Resolved
Jul 29, 2026, 06:46 PM UTC
Duration
3h 49m
Detected by Pingoru
Jul 29, 2026, 02:56 PM UTC

Affected components

Mishicot School District

Update timeline

  1. identified Jul 29, 2026, 02:56 PM UTC

    The WiscNet NOC has lost access to our device for **Mischicot Area School District** at **9:33am 7/29**. Please verify power to your site and the network equipment. If you are not aware of any internal work occurring and believe this is a network event, please contact GLS Tech Support for 24x7/outages/incidents at 866-558-1920. The TEACH ID for this circuit is **1132.** If you have any additional questions, please contact WiscNet NOC.

  2. identified Jul 29, 2026, 06:44 PM UTC

    Hello, We are able to access our device on site again. We will be closing out this status page now.

  3. resolved Jul 29, 2026, 06:46 PM UTC

    This incident has been resolved.

  4. postmortem Jul 29, 2026, 06:46 PM UTC

    Observed the OSPF adjacency go down as well as the physical interface indicating a loss of connection to the isp router, either due to a fiber cut or the device being unplugged.

Your product runs on more than WiscNet

Add the vendors you depend on and get one message when any of them reports trouble. Free for 3 vendors, no card.

Add your stack →